Hello all, i have a funny effect on a "HTTP Push Data Advanced Sensor" the setup is realy easy TLS= no (HTTP) Port= 5050 Requestmethode = GET Token = xxxxxxxxxxxxxxx
The recieved values are 1 to 3 = Error 4 is OK and if the sensor send nothing PRTG set the value to 0
I build a Lookup with for the different values incl the value 0
****************************************************************
<?xml version="1.0" encoding="UTF-8"?>
<ValueLookup id="xxx_App_Status" desiredValue="2" undefinedState="Error">
<Lookups>
<SingleInt state="Error" value="0">
not reachable
</SingleInt>
<SingleInt state="Error" value="1">
Stopped
</SingleInt>
<SingleInt state="Error" value="2">
Errored
</SingleInt>
<SingleInt state="Error" value="3">
Status unkown
</SingleInt>
<SingleInt state="Ok" value="4">
Ok
</SingleInt>
</Lookups>
</ValueLookup>
****************************************************************
This works fine
The sensor change to Error if the sensorchannel send the value 1,2,3
The sensor change to Ok if the sensorchannel send the value 4
But
if the sensorchannel revieve nothing and PRTG set the value to 0 the channel
will set it correct based on the lookup to "red" but the sensor will not change to Error
If i setup the alterting based on limits
Upper Error Limit = 4
Lower Error Limit = 4
It works fine
For me it will be nice to use a Lookup to give more informations about the Errortyp can you give me a workaround for this?