I imported the Cisco MIBs for monitoring client associations on the 5508 controller. However, when adding a sensor in PRTG, only generic SNMP and RFC sensors are available, and none of the Cisco sensors appear. What am I missing?



There's additional information regarding this matter on Cisco's Support Forum. Based on the supplied information, the key OID's for number of connected AP's and Clients are as follows:


Number of Connected Clients1.3.6.1.4.1.9.9.618.1.8.12.0
Number of Connected AP's1.3.6.1.4.1.9.9.618.1.8.4.0


This can be set-up using our SNMP Custom Sensor, limits can be configured on the "Value" channel after the sensor's creation.


Alternatively, you can import the CISCO-DOT11-ASSOCIATION-MIB and deploy an SNMP Library Sensor. Please refer to the following guide: Can't find a sensor for my device in PRTG but I believe it supports SNMP. How to proceed?