Receiving the error message: 209 % Delay (Interval Delay WMI) is above the error limit of 100 % Delay in Interval Delay WMI. WMI Sensors of this probe cannot be scanned in their specified intervals. Try longer intervals or distribute load over probes. — 248 Items (Open Requests) is above the warning limit of 100 Items in Open Requests


Do you have any WMI sensor down at this moment or in unknown status? If yes, please pause them. Also, you can increase the scanning interval on WMI sensors. Here's how: https://www.paessler.com/support/how-to/scanning-intervals

Furthermore, please check whether any WMI Sensors are in the down state. Those Sensors can also trigger such state. You can use this API Call to check for down WMI Sensors: HTTP(s)://YourPRTG/sensors.htm?filter_type=@sub(wmi)&filter_status=5


Disclaimer:
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.