I would like to avoid both servers in a cluster from polling at the same time. Is there another option to setting up a cluster where the data and configuration can be replicated to a standby server that is not actively running prtg. I would be doing this for Disaster Recovery and not as a failover.
Article Comments
Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.
Hello,
I'm afraid a disconnected cluster is not really possible. First of all, it wouldn't get the configuration this way from your main PRTG server. You could theoretically stop the Probe Service on the "Failover"-Node, but this would cause all sensors under the Cluster Probe to go into the "partial down"-state, which might not be what you actually want. In case you only want a proper backup for disaster recovery, we would actually recommend maybe to put PRTG onto a virtual machine and create a snapshot every night for example.
best regards.
Jun, 2011 - Permalink