hi,

I have two switches in VRRP, both are active, i need to monitoring which one is in use, is it possible?


Article Comments

Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.

The OID 1.3.6.1.2.1.68.1.3.1.3 holds the current state of the device and can take the following numerical values:

  1. initialize
  2. backup
  3. master

So you might want to use the SNMP Custom Sensor in combination with a Lookup.

Taken from http:cric.grenoble.cnrs.fr