We have some Moxa Insutrial Switches which I monitor with the snmptrafficsensor. Usualy the Traffic on this Switches is very low, just some kbit's But once a day I have a peak of 2 billions (10^12) in under one minute
where could be the problem of this? Its just a problem of the Switch? or can this be a problem of prtg or snmp? thanks Tobias
Article Comments
Dear Tobias,
the value could be a result of a volume counter overflow. Please open the Setting tab of the device object in PRTG, open the SNMP Compatibility Options, and check how the overflow handling is configured.
Dec, 2018 - Permalink
From what you mention you talk about traffic in general - SNMP and PRTG just show you how much data flows - the reason is normally something else - that's actually exactly why you should engage PRTG and SNMP to monitor this.
Regards
Florian Rossmark
www.it-admins.com
Dec, 2018 - Permalink