Hello
for some of my cisco devices, When I add Cisco health sensor it shows: CPU Memory Fan Power Supply Temp Voltage Currents Other
but for many of them only: CPU Memory Fan Power supply are available to choose.
How I can have all sensors for all?
Article Comments
Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.
Hi there,
Some Cisco devices do not offer any data for all Cisco System Health Sensor OIDs. This differs from device type to device type and firmware to firmware. Could you check if this is really the same for all devices you try to add the sensor to?
Best regards.
Sep, 2018 - Permalink
Did you download the device specific MIB files from Cisco and import them to PRTG?
Can you as well use a SNMP test tool to make sure those devices show / have the data available you are looking for?
Paessler offers such a tool as well here: https://www.paessler.com/tools/snmptester
Regards
Florian Rossmark
www.it-admins.com
Sep, 2018 - Permalink