Hello

When I create a Device Template it says all of my sensors is added to Template.

but When I want to use a Template by "Run Auto Discovery with Template" none of my sensors can be deployed on my new device.for example after deploying the mentioned attach screen,only ping sensor becomes available.Is it a normal behavior?


Article Comments

Hello Sara,
thank you for your KB-Post.

Please keep in mind that even when sensors were added to the template, they can only be deployed via the auto-discovery if the device on which you're running the discovery is compatible.

To confirm whenever the sensor can actually work on the device were you're running the discovery, please try and add the very same sensor manually. What's the outcome?

Please also refer to this guide for troubleshooting the discovery:

Best Regards,
Luciano Lingnau [Paessler Support]


Aug, 2018 - Permalink