Hi all,

is there a possibility to create a Sensor that monitor if a remote probe is up/down? I've got all of my sensors in 3 probes and when 1 of these probes go down I don't receive any error, and this is not good because if the remote probe go down I need to be informed asap.

How can I do it?


Article Comments

Hi Andrea,

When a remote probe is not reachable, this will lead to the probe health sensor on the remote probe to go into error state, you can add a state trigger there on tab "Notifications" in case there are currently none configured.

Additionally you can add each remote probe as a separate device to "Local Probe" of the PRTG server and monitor them with ping sensors and a service sensors that checks if service "PRTG Probe" is running.

Kind regards,

Erhard


May, 2018 - Permalink

thanks for the reply, it works well


May, 2018 - Permalink