Hi All, we have a Dell managed switch sending sFlow data to PRTG for bandwidth monitoring. I'm trying to monitor bandwidth usage for site-to-site VPN(s) that are set up as L2TP/IPSec connections. The sensor is set up to gather all ingress and egress traffic on the VPN endpoint IP, but nothing is showing up. A white paper on sFlow.org states that sFlow "supports" all L2-L7 traffic flows, so I'm guessing my PRTG sensor needs to be configured in a special way (??).
Is monitoring L2TP traffic via sFlow possible in PRTG and how do I set it up correctly?
Thx in advance for help and/or pointers! Rgds - Marcus.
PS: using v13.1.1.1181
Article Comments
Hi Torsten, thx for your reply. I updated to v14.2.9.1798 but after a couple of hours there's still no data showing up. I also deleted and recreated the sensor - still no luck.
Can you think of something else? I'm pretty sure I tried everything .. Thx again, Marcus.
Apr, 2014 - Permalink
To test if proper and compatible SFlow packets are arriving at the PRTG host, please use our SFlow Tester
Which results do you get in the tester? Please forward a screenshot or the logs from the tester.
Apr, 2014 - Permalink
Torsten,
nothing is being recorded in the sFlow Tester. I guess that means the switch is not sending sFlow version 5 data (??).
Thx - M.
Apr, 2014 - Permalink
It probably sends sflow that is not compatible to what PRTG expects. If you could upload a screenshot showing the results on the Tester, we may be able to say where exactly it fails.
Apr, 2014 - Permalink
Torsten, my apologies for the late reply - got sidetracked with other things.
I can certainly upload a screenshot, but as I said, nothing is displayed (just an empty screen). Can you confirm that PRTG is able to capture L2 traffic via sFlow?
Thx - M.
Jun, 2014 - Permalink
That most likely will mean the Sflow-Packets your device sends, are not compatible to PRTG.
Jun, 2014 - Permalink
Torsten - I would agree with that statement if I wasn't getting any data at all, but that's not the case - I am getting data, just not all of it.
I confirmed with Dell (which took a lot longer than it should...) that the switch does implement sFlow v5.
I reiterate my question: Can you confirm that PRTG is able to capture L2 traffic via sFlow?
Thx - M.
Jul, 2014 - Permalink
Torsten, I did a Wireshark capture and the switch is indeed sending the sFlow samples for the L2TP/IPSec traffic.
I compared one of these packets to another sFlow packet that is being recorded correctly in PRTG and can find no differences - other than the obvious (different protocols contained in the sampled packets).
Can I send you a screenshot of the L2TP flow sample and could you look over it why PRTG would not "understand" this sample?
Thx in advance - M.
Jul, 2014 - Permalink
I apologize, I just saw that my last response missed the crucial not. Layer2 traffic is not monitored by PRTG.
Jul, 2014 - Permalink
Hello,
I am having the same issue. We are trying to monitor and report on L2L IPSEC traffic, which is Layer 3 IP with protocol 50 (ESP). Packet captures display endpoint IP addresses, but nothing is displayed in PRTG channel. Is ESP tunnel mode considered Layer 2? It is encapsulated in Layer 3 IP.
Oct, 2014 - Permalink
Sorry, the sensor does not see the encapsulated Layer3 information, because it already disregards the Layer2-Packets.
Oct, 2014 - Permalink
This is too bad. I setup another Sflow collector to match Protocol 50 with the endpoint IP, and it records the data. I attempted using the channel definition of ((Protocol[50] and (SourceIP[x.x.x.x] or DestinationIP[x.x.x.x]), but it still did not record the same data as the other collector.
Oct, 2014 - Permalink
Then most likely the incoming traffic does not match the definition here. You can enable the stream logging on the Sflow-Sensor for all traffic to get the full details on the incoming traffic and help with such filter definitions.
Oct, 2014 - Permalink
Hello,
thank you very much for your KB-Post. Could you try updating to the newest version to see if that resolves the issue? If the newest version (14.2.9) isn't available for the auto-update you can download the software from the Customer Service Center. In order to access the download link to the newest version please log into your online account and download it there. Please use the email address the license is registered to and your password to log in here: https://service.paessler.com/en/login/