Hi, Can u help me , just a head start how to modify or create a new template that will show down sensors only in the report and not the green working sensors because it takes alot of time to review it if u have alot of sensors to report , I know u said in prev Questions u dont support this but can u consider it again ,I think many ppl would like an option like that will report only the down sensors !!!

Thanks


Article Comments

Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.

If you are looking for the sensors that are currently in a down state, you can do this through the sensor drop down in PRTG and see all of the down sensors. If you want to know which sensors went down for a certain time period, you can also show this through the logs drop down.

We don't have a report for this and likely will not build one since the database that is used for reporting doesn't keep historical up and down status messages.


Aug, 2014 - Permalink