Error in channel "cm_reg_total[]" (1) : Mixed delta and gauge channel. (code: PE2006)
Error in channel "cm_reg_total[]" (1) : Mixed delta and gauge channel. (code: PE2006)
Modified on 2025-06-10 13:48:38 +0200
Disclaimer:
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
Hello,
thank you very much for your KB-Post. I presume you did receive this error in a Sensor Factory Sensor. Please be aware that you cannot mix delta-type sensors (for example SNMP Traffic Sensors) with gauge-type sensors (for example a Disk Space Sensor). It is necessary to divide them into individual Factory Sensors.
best regards.