I have an ISA570 firewall setup with 2 internet connections coming in. I have both ports being monitored in PRTG. Once in a while I get a line that goes down, but PRTG never seems to recognize the connection as down. It seems to only show the connection as down when the port is physically disconnected. To find the connection, I normally have to manually refresh the sensor and look for "IN" traffic to be 0kb. This is how I know which line is down. Currently, I just had Errors In & out selected under Traffic specfic and now I enabled Discards In & Out, not sure if that will help. Let me know.
Thanks in advance.
Article Comments
Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.
Hello,
thank you very much for your KB-Post. If line down, here means that the connection is not physically down, but essentially not showing traffic, then I would suggest to set an Error-Limit on the sensor, for traffic "near to 0". This can be done in the Channel Settings of the Sensor.
best regards