I want to know that my network link work properly. Maybe you have other suggestions.
Article Comments
CRC errors can be obtained with locIfInCRC in the OLD-CISCO-INTERFACES-MIB (OID 1.3.6.1.4.1.9.2.2.1.1.12)
locIfInCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of input packets which had cyclic
redundancy checksum errors."
::= { lifEntry 12 }
Sep, 2011 - Permalink
You might be able to monitor CRC errors also with the SNMP RMON Sensor if your device provides traffic data via Remote Monitoring (RMON).
Jan, 2014 - Permalink
Hello,
have you checked the "Additional Channels" on the SNMP Traffic Sensors? Maybe this does already help. Otherwise it might be necessary to import MIBs from the vendor with our MIB Importer to check these values.
best regards.
Sep, 2011 - Permalink