Hello,

We had some HP Servers with Server 2012 and a working SNMP HP ProLiant System Health Sensor After Upgrade to Server 2012 R2 the SNMP Sensor Shows "No Such Name" HP WBEM Providers and Management Agents are installed

Best Regards


Article Comments

Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.

Hi, please check if the SNMP service/port is still available. Sometimes the OIDs will be change in different versions of the management agents. Please download our SNMP tester and try to connect to the device, for example the "Device uptime" is always available if the service is running and accessible.


Oct, 2013 - Permalink

Hi, SNMP is avaiable, using SNMP Memory Agent successfully on These Servers


Oct, 2013 - Permalink

please try to add the same sensor as a duplicate to the same server.


Oct, 2013 - Permalink

I have cloned the Sensor -> No Such Name Tried to add the Sensor new -> No Such Name What OID are u asking here?


Oct, 2013 - Permalink

The overall OID for this sensor is: 1.3.6.1.4.1.232.6.2.6.1.0 -> please try to read this value.


Oct, 2013 - Permalink

I have just found the Problem Upgraded HP Management Agents from 9.10 to 9.40 -> Now they work again


Oct, 2013 - Permalink