We are deploying many Images with a pre-installed remote probe. This cause by nature some problems because every remote probe has the same GID. Because I don't want to change them manually (Edit GID...) I'm looking for a solution to get a new GID randomly generated. Any Ideas?
Article Comments
Hi Torsten,
thanks for the quick reply! Seems that your Link has worked. I've experienced that deleting both values (Id and GId) from the registry (HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Paessler\PRTG Network Monitor\Probe) was necessary to get a new GID.
Thanks a lot!
Jun, 2013 - Permalink
Disclaimer:
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
Hello,
thank you very much for your KB-Post. Please see the solution in the following KB-Article: Probe GID deletion for creating a system image for distribution. I hope this helps.