Hi,
The default limit values for channel 9 - Voltage 4 (-11.95V) are in the wrong order.
The max is set per default at -14381 and the min at -9524
As these number are negative, the min should be -14381 and the max -9524
Manually correcting the values works for me.
Tested with a Cisco 7206 VXR and a Cisco ASR 1001F
Kind regards,
Marc
Article Comments
Thank you very much for that feedback.
At the moment, we're using ciscoEnvMonVoltageThresholdLow for the minimum and ciscoEnvMonVoltageThresholdHigh for the maximum. Seems like we've got to interpret those values as absolute values.
We'll fix this bug as soon as possible.
In the meantime, please swap the values in the channel settings.
Mar, 2013 - Permalink
Thank you very much for that feedback.
At the moment, we're using ciscoEnvMonVoltageThresholdLow for the minimum and ciscoEnvMonVoltageThresholdHigh for the maximum. Seems like we've got to interpret those values as absolute values.
We'll fix this bug as soon as possible.
In the meantime, please swap the values in the channel settings.
Mar, 2013 - Permalink