Running PRTG9. Will soon be upgrading to PRTG12
Here's my scenario. We have certain engineers who can add, modify, and remove sensors. I have another group which I would like to only be able to pause sensors as well as their normal "Read Only User" rights.
From what I am reading it seems that the existing setup allows you to only have "read only rights" or "full administrative rights". Is this correct?
Article Comments
Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.
Hello,
it also depends on the access rights set on the group/device/sensor. These can be set to None, Read, Write, Full. Only Full will be 'full administrative rights' to the object incl. deleting. 'Write' will not allow deleting in contrast. Read & None are probably clear.
best regards.
Dec, 2012 - Permalink