Hello,
We have purchased a license for PRTG. Since I added, there are some problems:
- The probe disconnects 5 minutes several times a day (State disconnected)
- There are about 600 sensors are in an unknown status. But before, the sensor works fine
There is a way to clear all caches, graphics to start with a clean base? So I would just keep my elements and probes
thank you
Article Comments
I have again the error : "Probe disconnected".. The probe is on the same server that the PRTG server.
I don't understand why the probe disconnected ? Have you got an idea ?
Jun, 2012 - Permalink
Hi,
no, Im afraid I have no idea. Please check if the probe service is running, if so please try restarting the same. Does that help?
EDIT: If the issue persits, please send your PRTG logs to supprt@@paessler.com.
Jun, 2012 - Permalink
Hi,
Yes I have tried to reboot many times but with no success.
And I don't understand why 600 sensors is not working properly since I have had the licence and install the commercial version. It's like there is no data to query.. And the auto-discover doesn't work anymore..
This is very strange..
Jun, 2012 - Permalink
Hi,
if I understood you correctly, you basically want to start with a configuration but without any data? If so, please stop all PRTG Services (Core and PRobe) then go to <PRTG Data Directory> and delete (resp. move away/rename) the folder "Monitoring Database". Then delete/move away/rename the file "PRTG Graph Data Cache.dat". Now start your PRTG Services again.
Does that resolve your issues?
Best regards
Jun, 2012 - Permalink