Hello everybody,
On some of my servers (with SQL Server and/or Business Object installed on it), I'm unable to use the "LastWindowsUpdateSensor".
PSRemoting is enabled, I checked the SPNs and created the "5985" SPN entries.
I'm able to enter a PSSession with the "includeportinspn" option
On my PRTG sensor, the "include port in SPN" box is checked
I try to manually check with the sensor but I'm unable to find the good arguments
I tried this command (I got it from the sensor log) :
LastWindowsUpdateSensor.exe -host=servername.myaddomain.tld -timeout=43198 -port=5985 -portinspn=1 -authmechanism=6 -debugfile="C:\ProgramData\Paessler\PRTG Network Monitor\Logs\sensors\Result of Sensor XXXX.log",
but the return is the following : Object reference not set to an instance of an object.
The result is the same when I just specify "host" and "port"
Thank you for your precious help
Article Comments
Hi Alexandre,
I'm happy to hear that you get it working. Thank you for sharing your troubleshooting steps.
Kind regards
Felix Wiesneth - Team Tech Support
May, 2021 - Permalink
The sensor is now working :
As a resolution, I :
- replaced FQDN with IP Address
- kept the "Include SPN" box checked
- kept the "Negotiate Authentication" box checked
May, 2021 - Permalink