I'm trying to analyze all my high performance impact sensors and decrease the frequency I scan them where possible. It would be great if there was a way to add the scanning interval column to the sensors.htm (?filter_size=4 or 5 for example) page so I could find any sensors we're scanning frequently.
Analyze Sensors with High Performance Impact, Filtered By Scanning Interval
Modified on 2025-06-10 15:16:18 +0200
Disclaimer:
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
Hi Paul,
I got you covered :)
For all sensors with a high performance impact use the following URL:
/sensors.htm?columns=size=htmllong,probegroupdevice=text,sensor=htmllong,status,message,lastvalue,minigraph,priority,favorite,interval,checkbox&filter_size=4
For all sensors with a very high performance impact use this URL:/sensors.htm?columns=size=htmllong,probegroupdevice=text,sensor=htmllong,status,message,lastvalue,minigraph,priority,favorite,interval,checkbox&filter_size=5
You can sort the view by Interval and use Multi-Edit to change the scanning interval of multiple sensors at once.Best,
Sebastian
Dec, 2020 - Permalink