Hello,

I just add a sensor sflow in a one alcatel devices, but the status is not data yet.

I'm tester with sflowtster 1.1.2 and it fails always in step 4.

My config in my router is:

sflow receiver 2 name PRTG address 172.26.131.242 udp-port 6343 packet-size 1400
version 5 timeout 0
sflow poller 1 port 1/1/1-50 receiver 2 interval 10
sflow poller 1 port 2/1/1-50 receiver 2 interval 10
sflow poller 1 port 3/1/1-50 receiver 2 interval 10
sflow poller 1 port 4/1/1-26 receiver 2 interval 10
sflow poller 1 port 5/1/1-50 receiver 2 interval 10
sflow poller 1 port 6/1/1-26 receiver 2 interval 10
ip service source-ip "VLAN-0151" sflow

Can you help me?

Thanks


Article Comments

Hello,

Please note that we cannot really offer assistance on configuration of target devices, since this may vary. Also, please note that PRTG only supports samples in "flow sample format". Is this the case? Extended flow is not supported. Are you able to see the sflow traffic via wireshark?


Oct, 2020 - Permalink