If "Inherit all triggers from parent objects and use the triggers defined above" is selected, does one override the other or do they both apply?

For example, my inheritance is "When sensor state is Down for at least 300 seconds, perform @ Outage Notification" and my explicit trigger is "When sensor state is Down for at least 600 seconds, perform @ Server Outage Notification".

What would happen when the sensor goes down in this scenario?


Article Comments

Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.

Hello SteveP,

Thanks for your KB post. Both notification triggers rule will be applied.

For more information, please have a look at our manual. https://www.paessler.com/manuals/prtg/sensor_notifications_settings

With kind regards,

Chan Siau Hen
Technical Support Team, Paessler AG