Hi there! I'm trying to get PRTG to only notify if ALL of the sensors are down in a group. For example, I have 2 devices per group, but I want to have a MS Teams & Email notification when both Devices are offline.


Article Comments

Hello there,

Thank you for your post.

Notifications can not be set to trigger only when all sensors are down. However you may be able to create a workaround by using the Factory Sensor or the Business Process Sensor. For this you could set up a Ping sensor on each device, and monitor with the Factory sensor or the Business sensor if all the Ping sensors are up (the assumption is that if the Ping sensor is down other sensors would be down as well). You could then have a notification trigger for the Factory sensor (or Business sensor), so that you get notified once all Ping sensors are down.


Kind regards,
Sasa Ignjatovic, Tech Support Team