Cisco IP SLA sensor with error #223
Modified on 2025-06-10 16:51:07 +0200
Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.
Important: We no longer maintain this article. The information might be out of date.
hi,
we are receiving error #223 when we search for IP SLA on an ASR router. other SNMP functions are working fine.
Article Comments
Hi there,
the error 223 is mostly seen if the target device does not provide the required OIDs. Did you validate that the device should support the Sensor?
You can use the SNMP Tester to validate this: https://www.paessler.com/tools/snmptester
These OID tables:
- 1.3.6.1.4.1.9.9.42.1.2.1
- 1.3.6.1.4.1.9.9.42.1.2.9
- 1.3.6.1.4.1.9.9.42.1.2.10
Dec, 2022 - Permalink
Disclaimer:
The information in the Paessler Knowledge Base comes without warranty of any kind. Use at your own risk. Before applying any instructions please exercise proper system administrator housekeeping. You must make sure that a proper backup of all your data is available.
Hi there,
the error 223 is mostly seen if the target device does not provide the required OIDs. Did you validate that the device should support the Sensor?
You can use the SNMP Tester to validate this: https://www.paessler.com/tools/snmptester
These OID tables:
Dec, 2022 - Permalink