The queries for the following channel IDs returned no data: 2 (code: PE269)


Article Comments

This error message occurs due the index of the required OIDs changed. In this case, PRTG does not "find" the corresponding information since the OID + index is wrong (comparable with wrong address where the street name is correct but not the house number).

To solve this error, you need to re-create the Sensor. In this case, a new metascan is triggered and the correct OID + Index is used again.