The queries for the following channel IDs returned no data: 2 (code: PE269)
Article Comments
Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.
This error message occurs due the index of the required OIDs changed. In this case, PRTG does not "find" the corresponding information since the OID + index is wrong (comparable with wrong address where the street name is correct but not the house number).
To solve this error, you need to re-create the Sensor. In this case, a new metascan is triggered and the correct OID + Index is used again.