After updating UCS Firmware to 3.1(3a), the Cisco UCS System Health sensor no longer show any values. Last Message: '' is not a valid integer value
What is causing this?
Article Comments
For anyone encountering a similar issue since updating the UCS to Firmware to 3.1(3a), in this particular case we've been able to get the sensors working again by enabling the Use single get Request Mode option within the Device's settings, under the SNMP Compatibility Options group.
However, this should be considered an interim solution and we encourage customers encountering this issue to contact Cisco's support, since it appears that multi-get SNMP queries are getting erratic replies, which is the cause for the errors in PRTG.
Best Regards,
Luciano Lingnau [Paessler Support]
Feb, 2018 - Permalink