I've added a custom sensor to my device. The sensor on PRTG constantly only shows "No Response (Error #2003)".
I downloaded and ran the 'SNMP Tester' tool with identical errors. A copy of the log is below:
----------------------- New Test ----------------------- Paessler SNMP Tester 5.2.3 Computername: HP-HP Interface: (192.168.1.117) 8/2/2017 11:30:16 AM (2 ms) : Device: 192.168.1.137 8/2/2017 11:30:16 AM (3 ms) : SNMP V2c 8/2/2017 11:30:16 AM (5 ms) : Custom OID 1.3.6.1.4.1.22154.3.1.2.5.1.2.6.0 8/2/2017 11:30:18 AM (2012 ms) : SNMP Datatype: ASN_PRIMITIVE 8/2/2017 11:30:18 AM (2014 ms) : ------- 8/2/2017 11:30:18 AM (2016 ms) : Value: No response (check: firewalls, routing, snmp settings of device, IPs, SNMP version, community, passwords etc) (SNMP error # -2003) 8/2/2017 11:30:18 AM (2018 ms) : Done
However, during this same test I kept Wireshark running to monitor what was actually being sent. Looking at the packets sent there, it shows a valid request and valid response, with the expected value from my sensor being sent. Wireshark was running on the same machine as SNMP Tester, meaning there's no possibility of differences in firewalls, ip conflicts, routing, etc.
A copy of the packet log of the response is below:
No. Time Source Destination Protocol Length Info 180 3.315765 192.168.1.137 192.168.1.117 SNMP 93 get-response 1.3.6.1.4.1.22154.3.1.2.5.1.2.6.0 Frame 180: 93 bytes on wire (744 bits), 93 bytes captured (744 bits) on interface 0 Internet Protocol Version 4, Src: 192.168.1.137, Dst: 192.168.1.117 User Datagram Protocol, Src Port: 161, Dst Port: 58800 Source Port: 161 Destination Port: 58800 Length: 59 Checksum: 0xa9fe [unverified] [Checksum Status: Unverified] [Stream index: 22] Simple Network Management Protocol version: version-1 (0) community: public data: get-response (2) get-response request-id: 1300 error-status: noError (0) error-index: 0 variable-bindings: 1 item 1.3.6.1.4.1.22154.3.1.2.5.1.2.6.0: 27473 Object Name: 1.3.6.1.4.1.22154.3.1.2.5.1.2.6.0 (iso.3.6.1.4.1.22154.3.1.2.5.1.2.6.0) Value (Integer32): 27473
"27473" is the correct expected value to be returned. The time delay between request/response is 0.005 seconds, so the PRTG certainly did not time-out.
What could be causing PRTG to not recognize this response?
Article Comments
Hi Luciano,
You are correct, setting the device to SNMPv1 on PRTG worked.
I thought I had seen on this device that it supported v2c. It is interesting that when receiving a v2c request it replies with v1.
Thanks for the support.
Aug, 2017 - Permalink
Hello derekm,
thank you your KB Post.
This looks very interesting. Your SNMP Tester log reads:
But the output from wireshark states that the reply was sent with SNMP V1:
If the query was sent in v2c, the device should reply in v2c. Set the SNMP Version to V1 in the Tester (and PRTG) and let me know how it works afterwards. :)
Best Regards,
Luciano Lingnau [Paessler Support]