I set up the sensor SNMP Trap Receiver. I want to see Warning status, if trap contains words Busyout.
Trap looks like:
- SNMPv2-MIB::snmpTrapOID.0 = G700-MG-MIB::cmgMgBusyout
- G700-MG-MIB::cmgTrapSubsystem.0 = HW
- G700-MG-MIB::cmgTrapOnBoard.0 = no
- G700-MG-MIB::cmgTrapLocation.0 = 149V
?? warning filter: bindings[Busyout] not working.
I need an exact match or the text should be contained in the message?
Article Comments
Dear tvaavt,
Thank you for your KB-post.
Please use the following binding bindings[1.3.6.1.4.1.6889.2.9.1.5.2.2.54] instead, because "G700-MG-MIB::cmgMgBusyout" is only the translation of the OID "1.3.6.1.4.1.6889.2.9.1.5.2.2.54" (as you can see here).
In case that this binding still does not work, please open a ticket, using the Ticket-ID PAE827523, and forward us screenshots of the tabs "Overview", "Messages" and "Settings" of your SNMP Trap Receiver sensor.
Best regards,
Sven
Feb, 2017 - Permalink
Dear tvaavt,
Thank you for your KB-post.
Please use the following binding bindings[1.3.6.1.4.1.6889.2.9.1.5.2.2.54] instead, because "G700-MG-MIB::cmgMgBusyout" is only the translation of the OID "1.3.6.1.4.1.6889.2.9.1.5.2.2.54" (as you can see here).
In case that this binding still does not work, please open a ticket, using the Ticket-ID PAE827523, and forward us screenshots of the tabs "Overview", "Messages" and "Settings" of your SNMP Trap Receiver sensor.
Best regards,
Sven
Feb, 2017 - Permalink