I am using Paessler Importer v3.4.7 and keep getting an this error "Something went wrong. Please check if all needed include/import files are in the stdmib or working path."

I have checked and verified that SNMPv2-SMI, SNMPv2-TC, SNMPv2-CONF, RFC1155-SMI are all in the /stdmib folder.

Any help is appreciated.... Here is the Mib file...

WNIP-BLADE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, 
    OBJECT-TYPE, 
    NOTIFICATION-TYPE,
    mib-2,
    Integer32, 
    Counter32, 
    Gauge32, 
    TimeTicks  
        FROM SNMPv2-SMI

    TEXTUAL-CONVENTION, 
    DisplayString,
    TruthValue, 
    DateAndTime, 
    AutonomousType   
        FROM SNMPv2-TC

    OBJECT-GROUP, 
    NOTIFICATION-GROUP, 
    MODULE-COMPLIANCE
        FROM SNMPv2-CONF

    enterprises
        FROM RFC1155-SMI;


-- 1.3.6.1.4.1.41260
WheatMibModule MODULE-IDENTITY
    LAST-UPDATED "201302050000Z"    -- 5 Feb 2013
    ORGANIZATION "Wheatstone Corporation"
    CONTACT-INFO
        "Wheatstone Corporation
        Postal: Wheatstone Corporation
                600 Industrial Dr.
                New Bern, NC 28562 USA
                USA
        Phone:  252-638-7000
        Fax:    585-637-1285
        Email:  info@wheatstone.com"
        
    DESCRIPTION
        "This MIB is for use in managing wheatstone systems."
    REVISION     "201302050000Z"
    DESCRIPTION
            "Second draft"
    ::= { enterprises 41260 }

-- 1.3.6.1.4.1.41260.100
wheatstone OBJECT IDENTIFIER ::= { WheatMibModule 100 }

-- 1.3.6.1.4.1.41260.100.1
blade             OBJECT IDENTIFIER ::= { wheatstone 1 }

-- 1.3.6.1.4.1.41260.100.1.1
bladeStatusEntry  OBJECT IDENTIFIER ::= { blade 1 }

-- 1.3.6.1.4.1.41260.100.1.2 
bladeTraps        OBJECT IDENTIFIER ::= { blade 3 }

-- 1.3.6.1.4.1.41260.100.1.3.0
bladeTraps0       OBJECT IDENTIFIER ::= { bladeTraps 0 }

-- 1.3.6.1.4.1.41260.100.1.3.1
bladeTrapData     OBJECT IDENTIFIER ::= { bladeTraps 1 }

-- 1.3.6.1.4.1.41260.100.1.1.1
bladeId OBJECT-TYPE
    SYNTAX        Integer32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "Blade Identifier."
    ::= { bladeStatusEntry 1 }

-- 1.3.6.1.4.1.41260.100.1.1.2
masterBladeId OBJECT-TYPE
    SYNTAX        Integer32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "Master Blade ID."
    ::= { bladeStatusEntry 2 }

-- 1.3.6.1.4.1.41260.100.1.1.3
cmasterBladeId OBJECT-TYPE
    SYNTAX        Integer32
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "Clock Master Blade ID."
    ::= { bladeStatusEntry 3 }

-- 1.3.6.1.4.1.41260.100.1.1.4
bladeName OBJECT-TYPE
    SYNTAX        DisplayString (SIZE (0..100))
    MAX-ACCESS    read-only
    STATUS        current
    DESCRIPTION   "Blade Name."
    ::= { bladeStatusEntry 4 }

-- 1.3.6.1.4.1.41260.100.1.3.1.1
bladeTrapBladeId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION   "Blade Id"
    ::= { bladeTrapData 1 }

-- 1.3.6.1.4.1.41260.100.1.3.1.2
bladeTrapBladeName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Blade Name"
    ::= { bladeTrapData 2 }

-- 1.3.6.1.4.1.41260.100.1.3.1.3
bladeTrapSignalName OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Signal Name"
    ::= { bladeTrapData 3 }

-- 1.3.6.1.4.1.41260.100.1.3.1.4
bladeTrapSignalLocation OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Signal Location"
    ::= { bladeTrapData 4 }

-- 1.3.6.1.4.1.41260.100.1.3.1.5
bladeTrapSignalId OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "The signal id."
    ::= { bladeTrapData 5 }

-- 1.3.6.1.4.1.41260.100.1.3.1.6
silenceDetectAudioState OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Silence Detector Audio State"
    ::= { bladeTrapData 6 }

-- 1.3.6.1.4.1.41260.100.1.3.1.7
silenceDetectSwitchState OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Silence Detector Switched State"
    ::= { bladeTrapData 7 }

-- 1.3.6.1.4.1.41260.100.1.3.1.8
bladeError OBJECT-TYPE
    SYNTAX      DisplayString (SIZE (0..100))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION "Error Message"
    ::= { bladeTrapData 8 }

-- 1.3.6.1.4.1.41260.100.1.3.0.1
SilenceDetectAudioAlarm NOTIFICATION-TYPE
    OBJECTS {
        bladeTrapBladeId,
        bladeTrapBladeName,
        bladeTrapSignalName,
        bladeTrapSignalLocation,
        bladeTrapSignalId,
        silenceDetectAudioState
        
    }
    STATUS current
    DESCRIPTION
        "A SilenceDetectAudioAlarm trap signifies that a blade destination has detected silence or audio has resumed."
    ::= { bladeTraps0 1 }

-- 1.3.6.1.4.1.41260.100.1.3.0.2
SilenceDetectSwitched NOTIFICATION-TYPE
    OBJECTS {
        bladeTrapBladeId,
        bladeTrapBladeName,
        bladeTrapSignalName,
        bladeTrapSignalLocation,
        bladeTrapSignalId,
        silenceDetectAudioState
    }
    STATUS current
    DESCRIPTION
        "A SilenceDetectSwitched trap signifies that a blade destination has been switched to primary or secondary."
    ::= { bladeTraps0 2 }

-- 1.3.6.1.4.1.41260.100.1.3.0.3
bladeSoftwareFault NOTIFICATION-TYPE
    OBJECTS {
        bladeTrapBladeId,
        bladeTrapBladeName,
        bladeError
    }
    STATUS current
    DESCRIPTION
        "A bladeSoftwareFault trap signifies the blade has encountered a fatal software failure."
    ::= { bladeTraps0 3 }

-- 1.3.6.1.4.1.41260.100.1.3.0.4
bladeCriticalError NOTIFICATION-TYPE
    OBJECTS {
        bladeTrapBladeId,
        bladeTrapBladeName,
        bladeError
    }
    STATUS current
    DESCRIPTION
        "A bladeCriticalError trap signifies the blade has encountered a critical problem that may hinder operation."
    ::= { bladeTraps0 4 }

END

Article Comments

Attention: This article is a record of a conversation with the Paessler support team. The information in this conversation is not updated to preserve the historical record. As a result, some of the information or recommendations in this conversation might be out of date.

We were able to import all elements compatible with SNMP Library sensors. Please forward us an email to support@paessler.com refering to this thread and we will forward you the imported OIDLIB file.


Oct, 2013 - Permalink